Warning: Trying to access array offset on value of type null in /home3/tomnetw1/tom3c/system/storage/modification/catalog/controller/common/header.php on line 37Warning: Trying to access array offset on value of type null in /home3/tomnetw1/tom3c/system/storage/modification/catalog/controller/common/header.php on line 39Warning: Trying to access array offset on value of type null in /home3/tomnetw1/tom3c/system/storage/modification/catalog/controller/common/header.php on line 41Warning: Trying to access array offset on value of type null in /home3/tomnetw1/tom3c/system/storage/modification/catalog/controller/common/header.php on line 43Warning: Trying to access array offset on value of type null in /home3/tomnetw1/tom3c/system/storage/modification/catalog/controller/common/header.php on line 45Warning: Trying to access array offset on value of type null in /home3/tomnetw1/tom3c/system/storage/modification/catalog/controller/common/header.php on line 47 DINTEK Cat 6A S/FTP Solid Cable With Braiding 305m - TOM3C | Networking
  • DINTEK Cat 6A S/FTP Solid Cable With Braiding 305m

DINTEK Cat 6A S/FTP Solid Cable With Braiding 305m

  • Brand: DINTEK
  • Model: 1105-06008
  • Location: Malaysia
  • Reward Points: 1019
  • Availability: In Stock
  • RM 1,019.00

  • Redeem Points: 101900

  • 6 or more RM 1,175.02
  • 12 or more RM 1,151.51


DINTEK PowerMAX+™ CAT.6A S/FTP Cable is specifically designed to support high speed network applications such as 10-Gigabit Ethernet . 

The cable is constructed of 4 screened pairs and a drain wire. DINTEK PowerMAX+™ CAT.6A S/FTP  cable minimizes alien crosstalk, provides excellent signal isolation and provides superior electromagnetic interference protection.

Conductor : 23AWG Bare Solid Copper
Jacket : PVC
Color : Gray

Applications

  • 10GBASE-T Ethernet

  • 100BASE-TX Fast Ethernet

  • 1000BASE-TX Gigabit Ethernet

  • 1000BASE-T Gigabit Ethernet

  • 10BASE-TX Ethernet

  • ATM CB1G

  • 155/622 Mbps ATM

  • 100 Mbps TP-PMD

  • 100VG-AnyLAN

  • 4/16 Mbps Token Ring

  • Voice

STANDARDS

  • UL Listed

  • CENELEC EN 50173-1, CENELEC EN 50288-10-1 for horizontal cable

  • ISO/IEC 2nd Edition 11801 Class EA 

  • IEC 3rd Edition 61935-1,IEC 2nd edition 61156-5 for horizontal cable

  • All proposed Category 6A Requirements as Per ANSI/TIA, ISO/IEC, and CENELEC EN Standard ANSI/TIA-568-C.2 Cat.6A

  • 3P Certified for Category 6A S/FTP installation Cable

  • Flame Retardancy is verified according to IEC 60332-1-2

  • Implemented ROHS Compliance for the Requirement of European Union Issued Directive 2002/95/EC

CABLE STRUCTURE 

  • Twisted pair color code:

  •    Pair 1>blue,white/blue ring

  •    Pair 2>orange, white/orange ring

  •    Pair 3>green, white/green ring

  •    Pair 4>brown, white/brown ring

  • Central Element: PE Cross Filler 

  • Jacket Type:  PVC / LSZH

  • Overall Diameter (mm):  7.8 * 9.1 ± 0.3

  • Color: Gray

PHYSICAL CHARACTERISTICS

  • Cold bend test:  -20 ± 20C X 4hrs no. crack

  • Dielectric strength: AC 1.7 KV for 2 s

  • Jacket Min elongation(%): Before (%100)     After Aging 50% (1000C X 168hrs)

  • Jacket Min. tensile strength(PSI) : Before 2000    After Aging 80% (1000C X 168hrs)

  • Insulation Min. tensile strength(PSI) before aging 1300     Tensile strength after aging :75% (at 1000C for 48hrs)

  • Insulation Min. Elongation (%) before aging 300    Min. elongation retention after aging: 75% ( 1000C x 48hrs:)

  • Dynamic Temperature: -100C to +60℃   Static Temperature: -100C to +60℃

ELECTRICAL CHARACTERISTICS

  • Spark test:2000 ± 250 V ac

  • Impedance: 125 Ohm 20%(64KHz). 100 Ohm 15%(1~500MHz)

  • D.C.R (Max.) : 9.38Ohm /100m at 20°C

  • D.C.R. Unbalance (Max.) : 2% MAX.

  • Mutual Capacitance: nom. 5600pf/100m

  • Capacitance, unbalance (Max.): 160 pF/100m

  • DC Insulation Resistance (Min.): 150M ohm/km

  • Dielectric Strength: 2500 Vdc / 3 seconds 